Tesla’s solar CT’s (connected directly to gateway, Nero’s are fine) are calibrated about 10% high. Probably on purpose so people think their solar is working well.
So if all loads are off, the solar CT’s should match the Line CT’s.
Seems like the calibration is looking for the lowest house...
Turn off all loads/breakers and let the solar calibrate with the main CT. I think Tesla finally figured out that their solar CT is off 10%. If all loads are off as well as Powerwall then solar has to match the main CT in the gateway.
Don’t turn off gateway main breaker, just the loads and let...
That is why I said “It would be cool if Tesla made a separate box”; and that is why it would have a disconnect switch.
It could even check the THD to protect Tesla’s hardware.
Would probably need some sort of circuit to help synchronize generator.
I would probably fork over 2K for said box...
It would be cool if Tesla made a separate box with a generator disconnect switch that could be connected to your generation panel. Probably require a few chips to connect to canbus and check for stable voltage and have CT’s to monitor load be applied to generator.
Tesla’s EVSE equipment is capable of load sharing. Even tho you have two charger circuits you could set the chargers to load share to play nicer to the grid, if that would work for your vehicle usage.
Because of the amount of utility scale solar on the grid, the rate is really low during the...
Have Tesla adjust your current limit in the software. This way the powerwalls will adjust the Powerwall draw to no trip your main breaker. You might think about EVSE that can PowerShare a single circuit too.
MPT/battery chargers can handle more power than the inverter. So perhaps Powerwall is charged already and is clipping what goes to the grid. Really only applies to PW3’s with a lot of solar.
Correct on edit. Inductive loads without correction cause the current to nearly double. Saw this with my well pump motor. I don’t have many capacitive loads, but it is possible some installed the wrong run capacitor on a motor that comes on.
What is the inductance of the load you applied that cause the voltage rise?
Do yourself a favor and buy DVM capable of real power measurement. Answer always lies there.
Leasing FSD. I purchased the performance upgrade for MY, car is always accelerating and deaccelerating. Software need to command power level not percent of power level.
I got the rheem 80 gallon heat pump heater. It is insulated very well from factor. Skin is ambient temps when I shoot it with or thermometer. So don’t know how well blanket will help. It has paid for its self already, did it at start of COVID before the prices doubled.
That was out of the video, with some shading.
Vines said Tesla inverters have a wide range on each mppt, and they do. But just know you will lose efficiency as the power will have to be converted by a buck/boost converter before the inverter and you will lose efficiency. I guarantee the...
Tesla LOVES to install two strings with one homerun, I believe that will affect production even more when shading occurs. I would like to see that test with different azimuths and pitch on a single string.
But in a nutshell, optimizers (including enphase) produces about 10-13% more energy...
V3 gateway probably contains a auto transformer and battery, umc would connect to gateway over can bus with battery power. Electronics need to run to disconnect grid and tell vehicle to turn on.
Contractor has to make his Yacht and RV payment! You don’t expect him to pay for that out of his pocket.
If I was this dude, I would get other quote for service upgrade, and two 200 amp service disconnect switches.
How could this dude be allowed to install 36.6Kw of solar on 200 amp service.
Quote for service upgraded didn’t include new transformer, just trenching and new equipment.
I’ve started running self powered. My utility will now pay me the avoidance cost (retail rate minus 4.5 cents) for my export, but I buy back at full retail rate. Should result in money in my pocket.
FSD is only worth 3K in my book. Prior to trial, I thought maybe 6K.
I might rent it for a long trip in the future.
All this has shown me is that my camera in the cabin is busted, fsd will not work at night.
My FSD trial started yesterday. tried it this morning, 6:00 am, and it wouldn’t engage as it was complaining that the camera was covered up. It isn’t covered, it is just dark out. Does my cabin camera need replacing?
Anyone else ?
Am I the only one? Sentry mode is disabled at home, work and favorites.
I’ve noticed the fan running much more often. If is very cool out, so it shouldn’t be running like it is.
I think a sensor is bad or something.
Grid outage, charging the MY with portable cord, two furnace on trying to drain powerwalls so solar returns. Might as well charge the car up, don’t want to let any power go to waste.
Fans in Powerwalls didn’t come, but it is in the 50’s.
What inverter profiles are you running on your none Tesla inverters?
I’m 99% sure your that is your issue.
I run “IEEE 1547 FW 61 to 62 Hz” on my enphase inverters.