  1. S

    Disappointing Power Generation, and I need help with analysis of pypowerwall output please!

    You are correct, the PW+ CT is indeed in the upper left corner, I had to move the wires aside and peek behind it, but it's there! Regarding shading, I've been taking a close watch on the two strings attached to the standalone inverter, and your theory was correct - MP5 is shaded at 2PM. It's on...
  2. S

    Disappointing Power Generation, and I need help with analysis of pypowerwall output please!

    I agree with this - I didn't see anything in the PW+ inverter that looked like the CT in the GW, and it would make sense that Tesla wouldn't put one into the PW+ inverter since the functionality is already there.
  3. S

    Disappointing Power Generation, and I need help with analysis of pypowerwall output please!

    Thanks, you're correct. I opened my gateway and found it (it appears gray in the photo, but it's actually black - this was taken in bright sun).
  4. S

    Disappointing Power Generation, and I need help with analysis of pypowerwall output please!

    At 11:25AM this morning, this is what I measured: Tesla App = 5.0 kW pypowerwall (B+C+D) = 2.285+0.930+0.831 = 4.046 kW PVWatts (July 1) = 6.1 kW So the Tesla App reports a value closer to PVWatts than pypowerwall, but still definitely lower. Thanks for the info on the CT; for some reason I...
  5. S

    Disappointing Power Generation, and I need help with analysis of pypowerwall output please!

    This makes sense. So if there is a Powerwall and standalone inverter in a system like mine, the App has to combine the data from the solar CT and from the Powerwall to get accurate power information. So the 726Wh that I calculated in my previous posts could indeed be the standalone inverter's...
  6. S

    Disappointing Power Generation, and I need help with analysis of pypowerwall output please!

    No, pypowerwall and the Tesla App don't match. I just checked 11:00AM Monday pypowerwall vs Tesla App, and the difference was 726Wh. Is this difference the output of the standalone inverter? I'm getting very confused.
  7. S

    Disappointing Power Generation, and I need help with analysis of pypowerwall output please!

    Nice call! The Tesla App GUI shows 4.8kWh at 11:00AM Monday. Does this mean the standalone inverter's output (MP2+MP5) was 726Wh? Both the app and pypowerwall I think should reflect all the string outputs. But all of this is very confusing so I'm not sure. For the PVWatts plot I picked a...
  8. S

    Disappointing Power Generation, and I need help with analysis of pypowerwall output please!

    Thanks for the feedback, I agree, I think output is low on mine. My PVWatts calculations matches Tesla's "commitment", and the actual performance for June is about 30% below this. Time to go argue with Tesla again!
  9. S

    Disappointing Power Generation, and I need help with analysis of pypowerwall output please!

    I also tried what you mentioned a few weeks ago (power cycling the standalone inverter, and I was able to connect to it via browser and 192.168.2.1. I recall it came online after a couple of minutes (2 or 3?), but stayed online for only about 15 minutes. It was very annoying and time consuming...
  10. S

    Disappointing Power Generation, and I need help with analysis of pypowerwall output please!

    That is exactly what I figured as well, thanks for the confirmation.
  11. S

    Disappointing Power Generation, and I need help with analysis of pypowerwall output please!

    Thanks for the detailed input. I was wondering about just these details and you've answered some questions I had. So there is just no way to get data from the standalone Tesla inverter with pypowerwall (I'm a new user and still learning)? The earlier data was taken at 11:00AM, so all panels...
  12. S

    Disappointing Power Generation, and I need help with analysis of pypowerwall output please!

    No worries, I really appreciate your detailed feedback!
  13. S

    Disappointing Power Generation, and I need help with analysis of pypowerwall output please!

    Could you clarify? Both PVWatts and the Tesla app show peak production at noon, with 11:00AM slightly less.
  14. S

    Disappointing Power Generation, and I need help with analysis of pypowerwall output please!

    Thanks for your recommendations and the technical details, this is great! When I speak to them, I will let them know.
  15. S

    Disappointing Power Generation, and I need help with analysis of pypowerwall output please!

    I used the default ac/dc ratio (1.2). Below is the full output (from example.py). I just used this code as a basis, didn't explore any other functions. If you need more info, let me know and I can figure out the other functions: Site Name: My Home - Firmware: 22.18.3 21c0ad81 - DIN...