You can install our site as a web app on your iOS device by utilizing the Add to Home Screen feature in Safari. Please see this thread for more details on this.
Note: This feature may not be available in some browsers.
Tesla's Supercharger Team was recently laid off. We discuss what this means for the company on today's TMC Podcast streaming live at 1PM PDT. You can watch on X or on YouTube where you can participate in the live chat.
Yes it seems they reverse-engineered (I wouldn't call this cracking a code) the protocol, but unfortunately they are not willing to share their findings. Again, this is not rocket science, but I do not have the time to do this anytime soon.
Some more analysis, as far as I can see there are just two different message types in master mode, but both carry the same data (byte order is just swapped) and both are 10 bytes long. I'll call them c0 messages (because they start with c0) and f8 messages (as they end in f8).
6A
c00d c0fe e1fc...
Alright, I tried in RS485 4wire mode (haven't tried RS422 mode yet) and received some stuff. Baud rate is 9600
Does anyone see the packet pattern here? Afaict its at least two different types in master mode, even more in slave mode.
Except for slave mode the packets are only send when...
Interesting that they labeled it RS485, afaik (this is also what Wikipedia says) RS485 is a 2wire bi-directional Bus, but they have discrete "IN" and "OUT" which would rather indicate RS422 (actually many claim RS422 is a substandard of RS485) which is what I assumed from the very beginning...
Thats exactly the opposite of what I have heard, saying that this would not be possible as SoC is not communicated over CP/PP and since its a standard Type1/2 connector such a functionality (while technically possible with some quirks like Supercharging over Type1/2) would not work with other...
Not sure if this has been discussed in the existing HPWC/WC thread yet, but for the sake of discussion (and people being able to find this info afterwards) I'm opening up a new thread to discuss this.
The new 80A single-phase (US) / 32A three-phase (EU) wall connector has an option to daisy...